## Scope

Agreement and reliability are related to correlation, but they are not the
same problem. Correlation describes co-movement. Agreement describes similarity
on the measurement scale itself. Reliability describes the proportion of
variation attributable to stable differences among subjects rather than to
measurement error or method disagreement.

This vignette covers the wide-data functions:

- `ccc()`
- `ba()`
- `icc()`

## Pairwise concordance and Bland-Altman analysis

Lin's concordance correlation coefficient combines precision and accuracy in a
single number. Bland-Altman analysis separates that question into estimated
bias and limits of agreement.

```{r}
library(matrixCorr)

set.seed(40)
ref <- rnorm(50, mean = 100, sd = 10)
m1 <- ref + rnorm(50, sd = 2)
m2 <- ref + 1.2 + rnorm(50, sd = 3)

fit_ba <- ba(m1, m2)
fit_ccc <- ccc(data.frame(m1 = m1, m2 = m2), ci = TRUE)

print(fit_ba)
summary(fit_ccc)
```

The two summaries are complementary rather than redundant. `ccc()` gives a
single concordance coefficient, while `ba()` makes the scale of disagreement
explicit.

## Pairwise ICC

`icc()` extends the wide-data reliability workflow in two directions. It can
return a pairwise matrix across method pairs, or it can return the overall
classical ICC table for the full set of methods.

```{r}
wide_methods <- data.frame(
  J1 = ref + rnorm(50, sd = 1.5),
  J2 = ref + 4.0 + rnorm(50, sd = 1.8),
  J3 = ref - 3.0 + rnorm(50, sd = 2.0),
  J4 = ref + rnorm(50, sd = 1.6)
)

fit_icc_pair <- icc(
  wide_methods,
  model = "twoway_random",
  type = "agreement",
  unit = "single",
  scope = "pairwise"
)

fit_icc_overall <- icc(
  wide_methods,
  model = "twoway_random",
  type = "agreement",
  unit = "single",
  scope = "overall",
  ci = TRUE
)

print(fit_icc_pair, digits = 2)
summary(fit_icc_pair)
print(fit_icc_overall)
```

## Pairwise versus overall ICC

This is the most important distinction in the ICC interface.

`scope = "pairwise"` answers:
"How reliable is each specific pair of methods?"

`scope = "overall"` answers:
"How reliable is the full set of methods when analysed jointly?"

Those are different quantities. The overall ICC cannot, in general, be
recovered by averaging the pairwise matrix.

## Consistency versus agreement

This simulation also includes systematic method bias, so it is a natural place
to contrast `type = "consistency"` with `type = "agreement"`.

```{r}
fit_icc_cons <- icc(
  wide_methods,
  model = "twoway_random",
  type = "consistency",
  unit = "single",
  scope = "overall",
  ci = FALSE
)

fit_icc_agr <- icc(
  wide_methods,
  model = "twoway_random",
  type = "agreement",
  unit = "single",
  scope = "overall",
  ci = FALSE
)

data.frame(
  type = c("consistency", "agreement"),
  selected_coefficient = c(
    attr(fit_icc_cons, "selected_coefficient"),
    attr(fit_icc_agr, "selected_coefficient")
  ),
  estimate = c(
    attr(fit_icc_cons, "selected_row")$estimate,
    attr(fit_icc_agr, "selected_row")$estimate
  )
)
```

Consistency discounts additive method shifts, whereas agreement penalises them.
When methods differ mainly by a systematic offset, consistency can therefore
look substantially better than agreement.

## Model, type, and unit

The classical ICC family is controlled by three arguments.

- `model` selects the one-way, two-way random, or two-way mixed formulation.
- `type` selects consistency or agreement.
- `unit` selects single-measure or average-measure reliability.

For pairwise ICC, average-measure output uses `k = 2` because each estimate is
based on exactly two methods. For overall ICC, average-measure output uses the
full number of analysed columns.

## Choosing among CCC, BA, and ICC

In practice these methods answer different questions.

- Use `ccc()` when one concordance coefficient per pair is the main target.
- Use `ba()` when the size and direction of disagreement should be visible on
  the original measurement scale.
- Use `icc()` when the target is reliability under a classical variance
  components interpretation.

There is overlap in interpretation, but these are not interchangeable
estimators.